Households · Electricity load calculator · kW & monthly units

Electricity Load Calculator

Connected load is the total kW of the appliances you have installed; a unit is a kilowatt-hour, watts × hours ÷ 1,000. Add your appliances to get both, sorted so the ones actually costing you money come first. Enter the hours each appliance is drawing power, not the hours it is plugged in.

Your appliances
ApplianceWattsHow manyHours / dayAt once
Choosing an appliance fills in a typical wattage; the rating plate on the appliance beats our table, so change it. Watts, not kW. A blank quantity counts as one. Tick “At once” for the appliances that run at the same time to see the load they draw together.
Use the number of days your bill covers (1 to 31). For a slab comparison the Consumer Service Manual’s basis is a 30-day month.
No tariff is built in. Your last bill total divided by its units gives an all-in average that includes fixed charges and taxes, not the rate one more unit costs; the Electricity Bill Calculator does a slab-by-slab bill.
From your bill or your DISCO sub-division. Compared with the total of the ratings you entered.
Shows the Consumer Service Manual’s 5 kW rule when the load you tick as running at once approaches it.

What is actually costing you

Worked example: five appliances, biggest first

ApplianceWattsHow manyHours / dayUnits / monthShareCost
Inverter AC, 1.5 ton1,200 W1828857.7%—
Ceiling fan80 W414134.426.9%—
Refrigerator, medium150 W1940.58.1%—
LED bulb12 W10621.64.3%—
Electric iron1,000 W10.5153.0%—

Connected load is each appliance’s watts times its quantity, added up: 1,200 + 320 + 150 + 120 + 1,000 = 2,790 W, or 2.79 kW. The household uses 16.65 units a day, 499.5 units over 30 days. The Inverter AC, 1.5 ton is 57.7% of it from one appliance; the 4 ceiling fans, at 26.9%, come second because they run 14 hours. The refrigerator’s 9 hours is an assumption for a cycling compressor. No tariff is built in, so the cost column is empty until you enter a rate.

Shown: an example household. Enter your own appliances above to replace it.

Air conditioning

How many units does an air conditioner use a month?

A 1.5-ton inverter air conditioner, taken at a typical 1,200 W, uses 288 units a month if it draws power for 8 hours a day over 30 days: 1,200 W × 8 hours = 9,600 Wh, or 9.6 units a day, and 9.6 × 30 = 288. At 4 hours a day the same unit uses 144. A 1-ton inverter unit at a typical 900 W uses 216 units at 8 hours, a 2-ton inverter unit at 1,700 W uses 408, and a non-inverter 1.5-ton unit at 1,800 W uses 432. These wattages are typical figures, not a specification: an inverter unit’s draw varies with the model, the weather and how hard the compressor is working, so check the rating plate on yours, and enter the hours the compressor is actually drawing power. One hour less a day on the 1,200 W unit is 36 units a month; a 10 W phone charger for 3 hours a day is 0.9. The rupee cost depends on your tariff slab, so take the units to the electricity bill calculator.

Connected, running and sanctioned

What is the difference between connected load and sanctioned load?

Connected load is the total load in kilowatts connected to the electric supply system or installed at the premises. Sanctioned load is the load in kilowatts sanctioned by the DISCO. The NEPRA Consumer Service Manual (Revised 2025) treats the load a new applicant declares on the application form as the connected load, subject to a test report from the Electric Inspector or an authorised wiring contractor and verification by the DISCO. The two meet when load grows: if you extend your load beyond the sanctioned load, a notice is issued and you must apply for extension within 15 days of receiving it, and the DISCO shall disconnect the supply if you fail to apply and complete the other formalities. Where a single-phase meter’s load approaches 5 kW, the manual provides for a notice to extend the load and for a time-of-use meter to be installed. The total this page gives is an estimate of connected load; what you draw at once is recorded by the meter as the month’s maximum demand. Compare the total with the sanctioned load on your own connection.

Source: NEPRA Consumer Service Manual (CSM), Revised 2025, definitions 23, 53 and 60, clauses 2.11.1, 2.12(1), 6.1.1.1 and 8.2.10, Annexure VI (Covering letter of 26 November 2025; read 2026-10-27).

Reference

How much electricity does each appliance use a month?

Units a month for one appliance at this page’s typical wattage, for 1, 4 and 8 hours a day over 30 days: watts × hours × 30 ÷ 1,000. Multiply by how many you have. A refrigerator, router or UPS runs all day but a compressor cycles, so read the 8-hour column as an assumption for a fridge and use 24 hours for a router or standby load.

Typical wattages, this site’s own figures (captured 19 September 2026); your rating plate beats them.
ApplianceTypical watts (our figures)1 h/day4 h/day8 h/day
Ceiling fan802.49.619.2
Pedestal or bracket fan651.957.815.6
Exhaust fan401.24.89.6
Air cooler20062448
Inverter AC, 1 ton90027108216
Inverter AC, 1.5 ton1,20036144288
Inverter AC, 2 ton1,70051204408
Non-inverter AC, 1 ton1,20036144288
Non-inverter AC, 1.5 ton1,80054216432
Electric room heater2,00060240480
LED bulb120.361.442.88
LED tube or ceiling panel200.62.44.8
Energy saver (CFL)250.7536
Incandescent bulb601.87.214.4
LED strip100.31.22.4
Refrigerator, medium1504.51836
Deep freezer20062448
Microwave oven1,20036144288
Electric kettle1,80054216432
Electric oven2,00060240480
Blender or juicer400124896
Toaster8002496192
Dishwasher1,50045180360
Washing machine, twin tub5001560120
Automatic washing machine2,00060240480
Spin dryer30093672
Vacuum cleaner1,20036144288
Electric iron1,00030120240
Water pump, 0.5 hp (motor output)37511.254590
Water pump, 1 hp (motor output)75022.590180
Water pump, 1.5 hp (motor output)1,12033.6134.4268.8
Electric geyser, instant3,00090360720
Water dispenser, hot and cold55016.566132
LED television, 32 inch501.5612
LED television, 55 inch1203.614.428.8
Desktop computer with monitor20062448
Laptop651.957.815.6
WiFi router100.31.22.4
Printer501.5612
UPS or inverter, standby draw300.93.67.2
Hair dryer1,50045180360
Sewing machine10031224
Air purifier501.5612
Phone charger100.31.22.4
Other appliance (enter its watts)0000

Pre-filled wattages for appliances common in Pakistani homes. They are the site's own round figures for each appliance type, not from a standard, a survey or a manufacturer, and some are rated input while some are typical running input (an inverter air conditioner's draw varies with the model, the weather and how hard the compressor is working). Every wattage on the page is editable; the rating plate on the appliance beats anything here. Water pump rows are the motor's output (hp x 746 W); the electrical input is higher, so use the plate's input watts (amps x volts) where it gives them.

Housing schemes

How is a house’s electrical load assessed by plot size?

For houses in housing schemes, Annexure VI of the Consumer Service Manual assesses load by plot size for a double-storey house (ground plus one): a plot up to 75 square yards at 3.15 kW, above 75 up to 125 at 5 kW, and so on to 17.74 kW above 600 up to 1,000 square yards; a single-storey house is taken as half. The assessment is used where the ultimate load of a scheme is worked out for electrification. When an individual connection is given, the load declared on the application form is treated as the connected load, subject to the test report and DISCO’s verification, so read Annexure VI as a benchmark for the plot, and the appliance total on this page as the figure you would declare for your own house. Plot sizes in marla convert to square yards in the land area converter.

Consumer Service Manual, Annexure VI: individual houses in housing schemes. The marla columns convert each band’s upper limit at 9 sq ft a square yard; a marla is 225 sq ft in Lahore district and 272 sq ft in other districts (Punjab Private Housing Schemes Rules 2022), and a kanal is 20 marla.
Plot size (square yards)Up to, in marla (225 sq ft, Lahore)Up to, in marla (272 sq ft)Double storey (kW)Single storey, half (kW)
Up to 753 marla2.5 marla3.151.58
Above 75 up to 1255 marla4.1 marla52.5
Above 125 up to 2008 marla6.6 marla5.72.85
Above 200 up to 25010 marla8.3 marla6.63.3
Above 250 up to 30012 marla9.9 marla7.453.73
Above 300 up to 35014 marla11.6 marla8.754.38
Above 350 up to 40016 marla13.2 marla9.54.75
Above 400 up to 5001 kanal16.5 marla10.615.31
Above 500 up to 60024 marla19.9 marla136.5
Above 600 up to 10002 kanal33.1 marla17.748.87

Reading the numbers

Why does my estimate differ from my meter?

Reading the result

Which appliances cost the most?

The share column shows which rows dominate your result. In most lists a few high-wattage, long-running appliances account for most of the units and many small devices for very little: in the example, one air conditioner is 57.7% of the month, and one hour less a day on it is 36 units, where a phone charger for 3 hours a day is 0.9.

Cross the result against your tariff

If your tariff moves you to a higher rate per unit at some monthly total, trimming your biggest consumer can be worth more than the units alone. This page does not know your tariff; enter your slab table in the electricity bill calculator to see where the boundaries fall, and the electricity bill tax calculator for the income tax on the bill.

Sizing solar from these figures

The daily units are the starting input, not the answer, and the rows you tick as running at once give the running load an inverter must carry; motors (air conditioners, pumps, refrigerators) draw several times their running watts for a moment at start-up, so an inverter needs headroom above that figure. The solar panel payback calculator works out generation, savings and payback; the net metering calculator settles the bill for units imported and exported.

Where this stops

This estimates units and compares ratings with a sanctioned figure you enter. What the units cost depends on your slab, your DISCO and the adjustments in that month, and whether an extension of load costs you anything depends on your tariff category; neither is worked out here.

FAQs

Electricity load calculator questions

How do I turn watts into units?

A unit is a kilowatt-hour. Multiply the wattage by the number of appliances and by the hours a day it draws power, then divide by 1,000 for units a day. A 1,200 W air conditioner run 8 hours a day is 1,200 x 8 / 1,000 = 9.6 units a day, 288 units in a 30-day month. In this page's example household (499.5 units a month) the air conditioner is 57.7% of the units.

My refrigerator is on 24 hours. Should I enter 24?

No. The compressor switches on and off, so entering 24 hours at the rating-plate wattage overstates its units. If the fridge's label or manual gives a yearly or daily kWh figure, use that. Otherwise the hours are your own estimate: 8 hours at 150 W is 1.2 units a day; 24 hours is 3.6, three times as much. The worked example uses 9 hours as an assumption.

What about an inverter air conditioner?

An inverter compressor varies its speed, so its draw is below its maximum for most of the time; a non-inverter compressor switches fully on and off. Entering the maximum rating for every hour overstates an inverter unit by an amount that depends on the model and the weather. The air conditioner rows here are typical running figures for each type, not maxima, so adjust hours or watts from your own unit's label rather than both.

Is connected load the same as my sanctioned load?

They are different things, and not necessarily the same figure. Connected load is the total kilowatts connected to the supply or installed at the premises; at connection it is the load declared on your application, subject to the wiring contractor's or Electric Inspector's test report and DISCO's verification. Sanctioned load is the load DISCO has sanctioned for your connection. The total on this page is the sum of the ratings you typed, an estimate of connected load. If you extend your load beyond the sanctioned load, DISCO issues a notice and you must apply for extension within 15 days or the supply can be disconnected (NEPRA Consumer Service Manual 2025, definitions 23 and 60, clauses 2.11.1 and 8.2.10). Check the sanctioned figure on your bill or with your sub-division.

Why does the cost look different from my bill?

A single rate per unit is a simplification. Residential tariff is slabbed by monthly units and the rate per unit depends on the slab and category your DISCO applies; the Electricity Bill Calculator takes your own slab table and shows both ways a slab can be applied. For a billing period longer than a month, the Consumer Service Manual pro-rates your units to 30 days to decide the slab and carries the excess forward (clause 6.1.1.1). On top of the energy charge a bill can carry fuel price adjustment, quarterly adjustment, electricity duty, GST, TV fee, fixed charges and withholding tax.

Where do the wattages come from?

They are this site's own round figures for common appliance types, used only to pre-fill the form: not from a standard, a survey or a manufacturer, and some are rated input while some are typical running input. The rating plate on your own appliance beats anything here, and every wattage on this page is editable for that reason. Water pump rows are the motor's output in horsepower converted to watts; the electrical input is higher.

Does standby power matter?

Devices left on all day still count. This page's router (10 W) and UPS or inverter standby (30 W) rows add up to 40 W, and 40 W for 24 hours is 40 x 24 x 30 / 1,000 = 28.8 units in a 30-day month. Enter any always-on device as a row with 24 hours.

Can I use this to size a solar system?

The daily units figure is the starting point, and the "runs at the same time" tick gives the load an inverter would have to carry, but sizing also needs when you use power through the day, roof orientation and shading, and what you want the system to cover. The Solar Panel Payback Calculator asks for a system size and the share of its output you use yourself; the Net Metering Calculator settles the bill for units imported and exported.

Does this work for a shop or an office?

The arithmetic is the same, but the tariff is not. Commercial connections are billed on their own tariff with their own fixed charges, and the Consumer Service Manual refers to a ToU tariff for connections of 5 kW and above, on which peak and off-peak units are priced separately. The units this page gives you are still valid; the cost line will not be.

Related tools

Now turn those units into a bill

Protected or unprotected slabs, the fixed charge per kW, fuel and quarterly adjustments, sales tax and section 235 tax, in the order they stack.

Open the Electricity Bill Calculator